CIMC-1E CLIP-ON MODEL GENERATOR SET
 
   
 

 

 

 

 

 

SPECIFICATIONS

 

Construction

CIMC-1E generator set is designed for mounting to the upper front structure of an ISO container. The design incorporates quick connections to the upper container corner castings. Additional attaching points on the container vertical structural members provide a secure mounting arrangement. It is a completely welded steel structural assembly designed to withstand minimum 3 g’s acceleration forces in all directions.

Structural Frame

The inner surface of the fuel tank is chemically cleaned and passivated, while the frame and outer surface of the fuel tank are primer coated with an epoxy ester chrome-free paint immediately after shot-blasting, and then finish coated with a high solids polyester baked-on enamel paint

Panels and Doors

(Galvanized Steel   Materials)

Metal-door, control box and receptacle box are chemically cleaned, passivated and chromate converted, prime coated with an epoxy-ester chrome-free paint, and finish coated with high polyester baked-on enamel paint

Hardware

All hardware and hinges are stainless steel or electroless nickel plated for maximum protection from salt water corrosion.

Dimensions

Width: 2310mm              Height: 1100mm   Depth: 660mm

Net Weight

950 kg (oil and coolant are included)

Operation Temperature

-40 to +55℃(-40°F to +131°F

Alternator Rating

15kW, 460 V, 60Hz

Battery

 

1) Maintenance free 12VDC

2) Cold Cranking Amps: 625Amps for 30 seconds at -18℃(0°F

Reserve capacity: 25Amps output for 160 min. at 27℃(80°F

3) Dimensions: 330 mm×173 mm×238 mm(13 in×6.8 in×9.8 in)

4) Terminal Posts: special threaded stainless steel studs 3/8-16

5) Battery charging current is supplied by a transformer and rectifier utilizing current from the AC generator . The battery charging circuit provides current with minimum of 12 amps

Electric Power Receptacle

 

Electric power receptacle shall be designed in accordance with the C.E.E. standards and I.E.C. recommended specifications, including I.S.O, and to operate when the nominal voltage measured among  phases is as below :

1) 60Hz; 400V min., 600V max.

2) 32 Amperes, 3 wire-4 pole, C.E.E. Earth contact position -3 h.

3) Bayonet retaining ring type as per attachment A

Options

Customer specified color

Customer specified number decals

230VAC or  460/230VAC dual output voltage

Mounting, header pin

Engine

 

Model

4TNE88-ECIMC (EPA type)

Type

Vertical, 4-cycle water-cooled diesel engine

Number of Cylinders

4

Bore×Stroke

88mm×90mm

Total Displacement

2.19L

Continuous Output

26.3hp/1800rpm

Maximum Output

35 hp /1800rpm

Cooling System 

Force-feed circulation radiator type cooling system

Coolant Volume 

8.0L (including reserve tank)

Radiator

Radiator is copper tubes with copper fins and dipped in corrosion resistant clear lacquer for protection from salt-water corrosion.

Cooling Fan

Fan material: nylon-plastics

Air flow rate: 52m3/min at 1800 r/min

Coolant Option

Engine cooling system topped with 55/45 mixture of antifreeze and water. Rating of -42°C

Lubricating System

Forced lubrication with trochoid pump, Oil flow rate: 10.6 L/min at 1800 r/min, 3kg/cm2

Oil Tank Capacity        

20L

Oil Type       

API classification CD or CF-4 grade 15w-40

Fuel Tank

Steel fuel tank is integrated in the frame, supplied with a brass anti-theft type drain valve at the bottom of the tank for purging contaminants and anti-theft type fuel filler necks, with net capacity of 475 liters (125gallons U.S). Two filler necks are located on opposite sides of the tank.

Automatic Air Bleed System

ON-OFF switch is in the ON position, the air bleed system works whether the generator set is operating or shutdown, and purges air from the injector pump and fuel supply lines.

In the case of long shutdown periods, the automatic air bleed system insures sufficient air free fuel available to the injectors to successfully start the engine without manually bleeding the lines and injector assembly.

Fuel Heater

Heat exchanger type utilizing engine coolant heat (option)

Fuel Filter

Primary filter with Water separator

Spin-on fuel filter, as secondary filter

Fuel Option

Use diesel fuel oil equivalent to or better than ISO 8217 DMA, BS 2869 Part 1 class A1 or Part 2 class A2 (Cetane Number: 45 min.)

Air Cleaner Type

Heavy-duty oil bath filter air cleaner

Starting System

Starting motor12VDC, 1.4kW

Starting Aid

Air heater 12VDC, 400W

Generator

 

Model

RF-15-CIMC

Type

1) RF-15-CIMC generator is manufactured in accordance with NEMA ODP type (IP22). It consists of main generator, AC brushless exciter, rotating diode, auxiliary winding, terminal box, etc.

2) Class H insulation per NEMA MG-1-1.65, maximum temp   rise:125.

3) The frame is made of steel plate. The design of stator lamination is unique. 10 lead wires is supplied.

4) Main rotor use the single piece 4-pole salient pole lamination, coupled with die cast or welding damping winding, field winding to form a unirotor construction, the field winding is layer wound with thermo setting epoxy for high mechanical and electrical integrity.

5)   Drive disc radial fan cooling method.

6) Laminations and wiring are protected against salt water with epoxy primers, epoxy impregnation (three times) and epoxy coating.

7) Dust-proof bearing, sealed and lubricated with synthetic hydrocarbon

Generator Rating

15kw(18.75 kVA) ,  460 V,  Phases: 3,  60 Hz

Control system

 

Protection Feature s

1) Safety stop control for engine low oil pressure

2) Safety stop control for engine high coolant temperature

3) Safety stop control for engine low coolant level

4) Safety stop control for generator low voltage

5) Safety stop control for generator lost phase

6) Safety stop control for generator short circuit or over load

7) Safety stop control for engine over speed

Automatic Restart Features

(Option)

The ERS1 model safety stop control unit features an automatic restarting capability that protects against so called “nuisance” shutdowns. If a generator set shutdown occurs, the ERS1 will initiate an automatic restart. If re-starting does not occur, the ERS1 will try again after a 10 minutes interval. A restart attempt will be initiated every 10 minutes until the generator set is successfully restarted or the battery charge is exhausted.

Gauges

Engine hour meter, water temperature gauge, oil pressure gauge, charging ammeter, fuel gauge

Unit Control

Preheat/start switch, on-off switch, Fault display unit

 

 

 
 
 